Problem: I have a problem with MB SD C4 DoIP multiplexer. When i open the SDconnect Toolkit, an error occurred. “Unknown Toolkit COM Server error 801” May I ask how to solve this problem. Free download error 801 bin file here https://mega.nz/file/udxC0T4I#Cu5bFZ2CaOHiN6x-oVxrrhfnyS2eDXHUGmIl-YC_RO0 Then replace this bin file in C:\Program Files (x86)\Mercedes-Benz\SDconnect Toolkit Then Open “TkAdministration” to run an firmware upgrade. How to Update MB SD C4 Plus DoIP Firmware without Battery? KT200 full version ecu programmer read and write Volvo Renault TRW EMS 2.2 and 2.3 without problem.
FOR ECUs TRW VOLVO TRUCK and RENAULT TRUCK EURO5, EURO6 TRW EMS 2.2 No need to open ECU cover for read and write. TRW EMS2.2 MPC5554 Renault Volvo diesel pinout
VOLVO RENAULT UD TRW EMS 2.2 WRITE IN SUCCESSFULLY TRW EMS2.3
TRW EMS 2.3 it can be done too, however, kt200 can not calculate checksum. Must be done with winols. But it works 100% R/W on bench. KT200 Full TRW EMS 2.3 MPC5674F Renault Volvo diesel pinout. Today did a 2010 Toyota Highlander Hybrid US model all keys lost, push to start with Autel IM608. It is time to try xhorse XM38 remote and APB112. It is so easy, using guided process, backup eeprom, generating simulator key, then add xm38 proximity in. WOW. Well done Autel. Little grieve is the xm38 doesn’t fit the toy48 emergency key every good. Had to squeeze in. Problem: I have chip “answer error” on immobox temic sprinter 2002 with autel im608 pro, it is not the same photo in autel and vvdi prog, that of vvdi prog corresponds well to reality. Which pins correspond to Pta0, ptc0 on apb108 cable? vvdi prog 2002-2005 Benz Sprinter Immo Box pinout Solution: VPP2 is missing in your wiring. this is wrong of the capacitor itself Or use vvdi prog easy job. There are 2 different quality KT200/KTM200 ecu programmer boards. And they are slightly different. One has a crossover board stuck to the back of the board and the other one does not. Looks like there have been revisions between them. The newest one was better quality soldering but looks like 2 chips have been hand soldered on and jumpers set differently.
One with cross overboard in the back is of very poor quality. One without cross-over board is a revision and is of better quality.
Good quality one without crossover on back. Better soldering also. Low quality with crossover The poor quality kt200 won’t even i.d certain modules. Sometimes the toolboot option is useless as it won’t work at all.
Where do you recommend to buy a well made kt200?
Always buy from an authorized dealer. Don’t look cheap. Obdii365.com have KT200 full and basic version with high-quality boards. It can do a full backup of edc15 (flash+eeprom) by pinout. No need to open and boot mode which is a rare feature. It has some functions that even my genuine kess3 and Autotuner doesnt.
Question: How can I use FCA SGW on Autel MaxiIM IM608, IM608 Pro or IM508? Is it possible to have a SGW subscription? I have 12+8 cable but I don’t want to spend time searching for sgw location. I want to use fca authentication by obd.
Answer: For diagnosis purpose Yes, you can bypass SGW thru AutoAuth, follow instructions to purchase license. how can i activate SGW Bypass (diagnosis) for FCA group in my autel? It is the as other Autel tablets. Autel Scan Tools Bypass SGW FCA Security Gateway Access If you are on North America, you can register on Autoauth and add your tools for use on FCA cars, that’s not fca credentials. Also on Europe, Texa tools have his own login for fca cars without register on fca or use witech. Autoauthh is only for diagnostics and you need internet. You will be able to erase codes, resets, special functions Etc. If you do diagnostics, then it’s worth the $50.
For Immobilizer function, it is a waste of time. No immo through OBD. AutoAuth doesn’t work for Key Programming/IMMO work. MaxiIM now can only unlock Renault gateway for immobilizer (Unlock Renault gateway). Autel cannot bypass FCA immobilizer yet. For 2018+ models, you will need 12+8 gateway adapter or Star cable (star cable bypasses the sgw connecting scanner to diagnostic CAN lines on the star connector). You’ll always need a bypass cable to pull Pin’s and program keys. http://blog.obdii365.com/2020/01/09/sgm-solution-for-chrysler-using-autel-fca-128-cable/ Yanhua Mini ACDP tech released new module 28 to clone ZF-9HP gearbox in boot mode. Supports Jaguar, Land rover, Chrysler, Dodge, Fiat, Honda, Jeep and other models of the ZF-9HP gearbox boot mode cloning. Module features:
How to Clone ZF-9HP Gearbox with Yanhua Mini ACDP Module 28? First of all connect interface with gearbox module follow the wiring diagrams Step 2: Prepare ACDP host, OBD+ICP adapter, interface board, gearbox and other accessories required for operation. Step 2: Confirm the location and definition of the test points for ZF-9HP gearbox computer Step 3: Install the copper pillars Step 4: Install the ZF-9HP boot interface board and lock it with copper pillars. Step 5: Install the ZF-9HP port interface board to the gearbox interface Step 6: Connect the ZF-9HP boot interface and the ZF-9HP port interface board with 8PIN cable Step 7: Short the CAN resistor on the OBP+ICP adapter to the “CAN-R Join” Step 8: Connect ACDP host, OBP+ICP adapter and ZF-9HP gearbox computer with 20PIN cable.
Run ACDP Mini App, go to Jaguar/Land rover-> Gearbox Clone->ZF-9HP (Boot) Identify Full read to backup data Full write data NOTE: For Honda, Fiat, Dodge and other models with 9HP gearbox, you enter same menu path as Jaguar Land rover. https://www.obdii365.com/wholesale/yanhua-mini-acdp-module-28-zf-9hp-gearbox-clone.html One of our customers’ Autel MaxiIM KM100 device automatically restarts every 5-10 minutes, in this case he will need a firmware reflash.
Free Download Autel KM100 flash files Installation instructions are mentioned, along with the boot files. Unzip this file and put it under the root directory>>Insert the SD card back into the device>>Reboot the device.
If still not working after flash firmware, need to send back device for repair. Many people are struggling to install Fetrotech Tool software on Windows 10 Pro operating system. Some of them has software crash or task bar disappear problem. Here is the customer solution and tested working great.
Here is the solution :
Desactiver windows defender, smartscreen etc…
Go in settings bar > Administration tools > Computer management > Local users and groups > Users, double click Admin and check that account is not disabled.
Go in task manager > type “powershell” then check run with admin privileges
type “net user admin /active:yes”
a confirmation message appears: the function was run something like that.
(The user’s Windows is french version, if you have english or other version, in powershell you must write the good name. You can use Net user to know the name of administrator account.)
Close the current user session (do not use change user)
Open the admin session
Go to tuner-box.com to download fetrotech software
Once done, go into task manager and then run a new task, use browse to retrieve the installation file. hitting run with admin privileges.
continue the installation to the end.
once done, open chrome (or other browser) by right-clicking then run as admin, recover activation files by downloading fetrotool file directly to C:/ and fetrotech 3.5ok. license in c:/x86 files programs/fetrotech
open windows explorer then go to c:/ right click>ownership and check unlock> apply>OK
do the same on the fetrotech file 3.5ok. license in c:/x86 files programs/fetrotech
still in the file c:/programs files x86/fetrotech, right click on Fetrotech Tool. exe then in compatibility check Run as admin > OK
Plug in fetrotech to a usb port
Drag the fetrotech file 3.5ok. license from Fetrotech Tool. ex
Fetrotech should open up .
You can now use shortcut on the desk
If software won’t start after, check usb cable, unplug and plug, that’s why not running at first try. Always close all windows user session. Keep only administrator account when you wanna use Fetrotech.
During the launch the mouse stops moving for a few moments during the launch, the spot bar disappears and returns directly.
If the mouse keeps moving while loading, it will not work (in his case)
Keep in mind that only the admin session should be open, if your classic session is also open it won’t work (in my house anyway) and you’ll have the same worries as everyone else.
In this case you need to close admin session, then go back to regular session, use Log out, then reopen admin session.
The only problem with this method is that the admin session won’t contain your usual documents/software but you can start them from Programs files if you know their locations.
|
AuthorCategories |